BKRVN - GALVA-TEK AEROSOL, 5028
- MSDS: BKRVN
- Manufacturer: CERTIFIED LABS DIV OF NCH CORP
- Product Name: GALVA-TEK AEROSOL, 5028
- National Stock Number: 6520-00N016253
Product Identification
Product ID:GALVA-TEK AEROSOL, 5028
MSDS Date:04/26/1990
FSC:6520
NIIN:00N016253
MSDS Number: BKRVN
Responsible Party
US
Emergency Phone: 214-438-1381
Info Phone: 214-438-1381
Preparer: KELLY SEALS
Cage: 20913
Contractor
Telephone: 972-438-0563
Cage: 20913
Ingredients
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
BENZIN (ALIPHATIC PETROLEUM DISTILLATE)
CAS: 8030-30-6
RTECS: DE3030000
OSHA PEL 100 PPM
METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)
CAS: 78-93-3
RTECS: EL6475000
OSHA PEL 200 PPM/300 STEL
ACGIH TLV: 200 PPM/300STEL 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
METHYLENE CHLORIDE (SARA III)
CAS: 75-09-2
RTECS: PA8050000
OSHA PEL 500 PPM/C,1000; Z2
ACGIH TLV: 50 PPM, A2; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PROPANE
CAS: 74-98-6
RTECS: TX2275000
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT; 9192
EXPOS HAVING NO EFT ON MOTHER SHOULD HAVE NO EFT
RTECS: 9999999ZZ
HAVE PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN
RTECS: 9999999ZZ
ADRENOMIMETICS (I.E, EPINEPHRINE) MAY BE
RTECS: 9999999ZZ
ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS OR
RTECS: 9999999ZZ
IF >2.0 ML/KG HAS BEEN
RTECS: 9999999ZZ
KEEP HEAD BELOW HIPS TO AVOID ASPIR. IF GAG REFLEX
RTECS: 9999999ZZ
A CUFFED ENDOTRACHEAL TUBE IS INDICATED.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:LD50:ING 1(ORAL,RAT)>5.2G/KG (SUPP DATA)
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL: SLIGHT IRRIT TO MUC MEMB
WHICH CAN LEAD TO CNS DEPRESS W/EFTS OF HDCH,DIZZ,NAUSEA & LOSS OF
CONSCIOUSNESS.EYE IRRIT. DEFATS SKIN WHICH CAN LEAD TO IRRIT.
INGEST: MAY RESULT IN VOMIT: ASPI R MUST BE AVOIDED TO AVOID CHEM
PNEUMONITIS. CHRONIC: SKIN/EYES: MARKED IRRIT FROM OVEREXP.
MASSIVE(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE LISTED NTP-2;
IARC-2B.
Effects of Overexposure:HLTH HAZ: CONTINUAL OVEREXP CAN LEAD TO
LIVER/KIDNEY DAMAGE.TARGET ORGANS: LIVER/KIDNEY. SYSTEMIC & OTHER
EFTS: EXCESS EXPOS MAY CAUSE CNS/LIVER OR KIDNEY EFTS. METHYLENE
CHLORIDE HAS BEEN SHOWN TO IN CREASE THE RATE OF SPONT OCCURING
MALIGNANT TUMORS IN 1 STRAIN OF LAB MOUSE & BENIGN TUMORS IN LAB
RATS. (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:GET PERSON OUT OF AREA TO FRESH AIR. IF BRTHG STOPPED
ARTF RESP SHOULD BE STARTED. O*2 MAY BE GIVEN. SEE MD IMMED.
EYE:FLUSH W/LRG AMTS OF H*2O FOR AT LST 15 MIN LIFTING UPPER &
LOWER LIDS OCCAS . GET MD IF IRRIT CONT. SKIN:THORO WASHEXPO AREA
W/SOAP & H*2O. REMOVE CONTAMD CLTH.LAUNDER BEFORE REUSE. APPLY
EMOLLIENT RICH CREAM. INGEST:DO NOT INDUCE VOMIT. IF VOMIT OCCURS
SPONT KEEP(SEE ING10)
Fire Fighting
Flash Point Method:TCC
Flash Point:81.0F,27.2C
Lower Limits:1%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL
Fire Fighting Procedures:EVACUATE HAZ AREA OF UNPROTECTED PERSONNEL.
WEAR PROT CLTHG INCLUDING NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
. COOL FIRE-EXPOS CNTNRS W/WATER.
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL
TO AREAS DISTANT FROM HANDLING POINT. THERMAL DECOMP PRODS MAY
INCLUDE HCL & PHOSGENE .
Accidental Release
Spill Release Procedures:PICK UP WITH AN ABSORBENT SUCH AS PAPER,
VERMICULITE, ETC TO CONTAIN SPILL. DO NOT FLUSH TO SEWER. PLACE
INTO LABELED CONTAINERS AND SEAL. WET VACUUM AREA AFTER ALL TRACES
HAVE BEEN CLEANED UP.
Handling
Handling and Storage Precautions:KEEP AWAY FROM ALL IGNITION SOURCES.
STORE AT MODERATE TEMPS. FLAMMABLE. STORAGE TEMP: 120 F(MAX) - 0
F(MIN).
Other Precautions:READ ENTIRE LABEL BEFORE USING PROD. KEEP OUT OF
REACH OF CHILDREN. NO SMOKING IN AREA OF USE. DO NOT USE IN GEN
VICIN OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE THE FORM OF HCL &/OR PHOSGENE .
Exposure Controls
Respiratory Protection:TYPICAL USE DOES NOT REQUIRE RESPIRATORS.
HOWEVER, IN EMER SITUATIONS WHERE EXPOS EXCEEDS OCCUP LIMITS, USE
THE FOLLOWING NIOSH/MSHA APPRVD RESPS: 1000 PPM:CCROVF. 5000 PPM:
GMOV/SAF/SCBAF. 10,000 PPM : SAF=PD, PP, CF. ESCAPE: GMOV/SCBA.
Ventilation:LOCAL EXHAUST VENT SUFFICIENT TO MAINTAIN WORKPLACE CONC
BELOW PEL.
Protective Gloves:NEOPRENE RUBBER GLOVES
Eye Protection:CHEMICAL WORKERS GOGGLES
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
LD50-LC50 MIX: ING 2:(ORAL,RAT) 28 G/KG,(ORAL,RBT)28 G/KG. ING
3:(ORAL,RAT) 3.3 G/KG. EFTS OF OVEREXP: ANIMAL STUDIES & SEVERAL
HUMAN EPIDEMIOLOGY STUDIES FAILED TO SHOW TUMORIGENIC RESPONSE
RELATED T O METHYLENE CHLORIDE. NOT BELIEVED TO POSE ANY CARC RISK
TO MAN WHEN HNDLD AS REC. BIRTH DEFECTS UNLIKELY. (SEE ING 7)
Chemical Properties
HCC:V3
Boiling Pt:B.P. Text:105F,41C
Vapor Pres:85
Vapor Density:3.0
Spec Gravity:0.890
Evaporation Rate & Reference:5.0 (BUTYL ACETATE =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:GRAYISH-SILVER COLOR; OPAQUE, XYLENE ODOR
Percent Volatiles by Volume:66 %
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Hazardous Decomposition Products:CARBON MONOXIDE AND TRACE AMOUNTS OF
PHOSGENE. HCL .
Disposal
Waste Disposal Methods:DO NOT INCINERATE OR PUNCTURE CAN. DISPOSE OF
CAN ALONG W/CONTAMD ABSORBENT IN APPROVED SANITARY LANDFILL.
DISPOSE OF IN ACCORDANCE W/FED, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.