XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


BENZIN (ALIPHATIC PETROLEUM DISTILLATE)

CAS: 8030-30-6

RTECS: DE3030000

OSHA PEL 100 PPM


METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

OSHA PEL 200 PPM/300 STEL

ACGIH TLV: 200 PPM/300STEL 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPANE

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9192


EXPOS HAVING NO EFT ON MOTHER SHOULD HAVE NO EFT

RTECS: 9999999ZZ


HAVE PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN

RTECS: 9999999ZZ


ADRENOMIMETICS (I.E, EPINEPHRINE) MAY BE

RTECS: 9999999ZZ


ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS OR

RTECS: 9999999ZZ


IF >2.0 ML/KG HAS BEEN

RTECS: 9999999ZZ


KEEP HEAD BELOW HIPS TO AVOID ASPIR. IF GAG REFLEX

RTECS: 9999999ZZ


A CUFFED ENDOTRACHEAL TUBE IS INDICATED.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:ING 1(ORAL,RAT)>5.2G/KG (SUPP DATA)
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL: SLIGHT IRRIT TO MUC MEMB
WHICH CAN LEAD TO CNS DEPRESS W/EFTS OF HDCH,DIZZ,NAUSEA & LOSS OF
CONSCIOUSNESS.EYE IRRIT. DEFATS SKIN WHICH CAN LEAD TO IRRIT.
INGEST: MAY RESULT IN VOMIT: ASPI R MUST BE AVOIDED TO AVOID CHEM
PNEUMONITIS. CHRONIC: SKIN/EYES: MARKED IRRIT FROM OVEREXP.
MASSIVE(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE LISTED NTP-2;
IARC-2B.
Effects of Overexposure:HLTH HAZ: CONTINUAL OVEREXP CAN LEAD TO
LIVER/KIDNEY DAMAGE.TARGET ORGANS: LIVER/KIDNEY. SYSTEMIC & OTHER
EFTS: EXCESS EXPOS MAY CAUSE CNS/LIVER OR KIDNEY EFTS. METHYLENE
CHLORIDE HAS BEEN SHOWN TO IN CREASE THE RATE OF SPONT OCCURING
MALIGNANT TUMORS IN 1 STRAIN OF LAB MOUSE & BENIGN TUMORS IN LAB
RATS. (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:GET PERSON OUT OF AREA TO FRESH AIR. IF BRTHG STOPPED
ARTF RESP SHOULD BE STARTED. O*2 MAY BE GIVEN. SEE MD IMMED.
EYE:FLUSH W/LRG AMTS OF H*2O FOR AT LST 15 MIN LIFTING UPPER &
LOWER LIDS OCCAS . GET MD IF IRRIT CONT. SKIN:THORO WASHEXPO AREA
W/SOAP & H*2O. REMOVE CONTAMD CLTH.LAUNDER BEFORE REUSE. APPLY
EMOLLIENT RICH CREAM. INGEST:DO NOT INDUCE VOMIT. IF VOMIT OCCURS
SPONT KEEP(SEE ING10)

Fire Fighting

Flash Point Method:TCC
Flash Point:81.0F,27.2C
Lower Limits:1%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL
Fire Fighting Procedures:EVACUATE HAZ AREA OF UNPROTECTED PERSONNEL.
WEAR PROT CLTHG INCLUDING NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
. COOL FIRE-EXPOS CNTNRS W/WATER.
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL
TO AREAS DISTANT FROM HANDLING POINT. THERMAL DECOMP PRODS MAY
INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:PICK UP WITH AN ABSORBENT SUCH AS PAPER,
VERMICULITE, ETC TO CONTAIN SPILL. DO NOT FLUSH TO SEWER. PLACE
INTO LABELED CONTAINERS AND SEAL. WET VACUUM AREA AFTER ALL TRACES
HAVE BEEN CLEANED UP.

Handling

Handling and Storage Precautions:KEEP AWAY FROM ALL IGNITION SOURCES.
STORE AT MODERATE TEMPS. FLAMMABLE. STORAGE TEMP: 120 F(MAX) - 0
F(MIN).
Other Precautions:READ ENTIRE LABEL BEFORE USING PROD. KEEP OUT OF
REACH OF CHILDREN. NO SMOKING IN AREA OF USE. DO NOT USE IN GEN
VICIN OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE THE FORM OF HCL &/OR PHOSGENE .

Exposure Controls

Respiratory Protection:TYPICAL USE DOES NOT REQUIRE RESPIRATORS.
HOWEVER, IN EMER SITUATIONS WHERE EXPOS EXCEEDS OCCUP LIMITS, USE
THE FOLLOWING NIOSH/MSHA APPRVD RESPS: 1000 PPM:CCROVF. 5000 PPM:
GMOV/SAF/SCBAF. 10,000 PPM : SAF=PD, PP, CF. ESCAPE: GMOV/SCBA.
Ventilation:LOCAL EXHAUST VENT SUFFICIENT TO MAINTAIN WORKPLACE CONC
BELOW PEL.
Protective Gloves:NEOPRENE RUBBER GLOVES
Eye Protection:CHEMICAL WORKERS GOGGLES
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
LD50-LC50 MIX: ING 2:(ORAL,RAT) 28 G/KG,(ORAL,RBT)28 G/KG. ING
3:(ORAL,RAT) 3.3 G/KG. EFTS OF OVEREXP: ANIMAL STUDIES & SEVERAL
HUMAN EPIDEMIOLOGY STUDIES FAILED TO SHOW TUMORIGENIC RESPONSE
RELATED T O METHYLENE CHLORIDE. NOT BELIEVED TO POSE ANY CARC RISK
TO MAN WHEN HNDLD AS REC. BIRTH DEFECTS UNLIKELY. (SEE ING 7)

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:105F,41C
Vapor Pres:85
Vapor Density:3.0
Spec Gravity:0.890
Evaporation Rate & Reference:5.0 (BUTYL ACETATE =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:GRAYISH-SILVER COLOR; OPAQUE, XYLENE ODOR
Percent Volatiles by Volume:66 %

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Hazardous Decomposition Products:CARBON MONOXIDE AND TRACE AMOUNTS OF
PHOSGENE. HCL .

Disposal

Waste Disposal Methods:DO NOT INCINERATE OR PUNCTURE CAN. DISPOSE OF
CAN ALONG W/CONTAMD ABSORBENT IN APPROVED SANITARY LANDFILL.
DISPOSE OF IN ACCORDANCE W/FED, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.